Greaves gensets in the 5 and 7.5 kVA range deliver reliable, efficient power outputs of 5/4 and 7.5/6 kVA/kWe, powered by single-cylinder mechanical engines with air- or water-cooling. With NSM alternators, Class H insulation, ±5% voltage regulation, and DSE 4520 controllers, they provide CPCB-IV+ compliant performance in a compact, lightweight, and durable design ideal for residential, office, and small commercial needs.
Greaves 10–20 kVA gensets deliver dependable power for residential, commercial, and light industrial needs with outputs of 10/8, 15/12, and 20/16 kVA/kWe. Powered by robust 2–3 cylinder engines with water-cooled or TCAC systems, they feature LS/CG alternators, Class H insulation, ±1% voltage regulation, and SGC 120 MKII controllers, ensuring fuel efficiency, durability, and compliance with ISO 8528 standards in a compact design.
Greaves 25–40 kVA gensets deliver dependable outputs of 25/20, 30/24, and 40/32 kVA/kWe, powered by the proven 3G11TAG31 three-cylinder mechanical engine with advanced TCAC cooling for efficiency and durability. Featuring LS/CG alternators, Class H insulation, ±1% voltage regulation, and SGC 120 MKII controllers, they ensure stable, reliable, CPCB-compliant operation in a compact, easy-to-install design weighing 900–1180 kg.
Greaves gensets in the 45, 50, and 58.5 kVA range deliver reliable outputs of 45/36, 50/40, and 58.5/46.8 kVA/kWe, powered by the 3G11TAG31 three-cylinder mechanical engine with TCAC cooling. With LS/CG alternators, Class H insulation, ±1% voltage regulation, and SGC 120 MKII controllers, they ensure CPCB-IV+ compliant performance in a compact, durable design well-suited for long-lasting commercial use.
Greaves gensets in the 75 and 82.5 kVA range deliver dependable outputs of 75/60 and 82.5/66 kVA/kWe, powered by the advanced 3G11TAG41 CRDI engine with efficient TCAC cooling. With LS/CG alternators, Class H insulation, ±1% voltage regulation, and DSE 6120 MKIII controllers, they ensure reliable, CPCB-IV+ compliant performance in a compact, robust design built for long-lasting, heavy-duty reliability.
Greaves gensets in the 100 and 125 kVA range deliver dependable outputs of 100/80 and 125/100 kVA/kWe, powered by 4G11TAG CRDI engines with advanced TCAC cooling for durability and efficiency. With LS/CG alternators, Class H insulation, ±1% voltage regulation, and DSE 6120 MKIII controllers, they provide CPCB-IV+ compliant performance in a compact, fuel-efficient design built for long-lasting reliability.
Greaves gensets in the 160, 180, 200, and 250 kVA range deliver dependable outputs from 160/128 to 250/200 kVA/kWe, powered by 6-cylinder CRDI TCAC engines for superior efficiency and long-term durability. With LS/CG alternators, Class H insulation, ±1% voltage regulation, and DSE 6120 MKIII controllers, they provide stable CPCB-IV+ compliant performance in a compact, fuel-efficient design built for dependable industrial use.
Greaves gensets in the 320, 400, and 500 kVA range deliver dependable, efficient outputs with CRDI and mechanical TCAC engines, paired with LS/CG alternators, Class H insulation, ±1% voltage regulation, and DSE 6120 MKIII controllers. Fully CPCB-IV+ compliant with advanced DEF-based aftertreatment, large fuel capacity, and compact heavy-duty designs, they ensure long-lasting, consistent, and reliable performance.
The Greaves GPW-PIV-625M delivers 625/500 kVA/kWe prime output, powered by the 12V15TAG51 V12 TCAC engine with an electronic G3-class governor. With Stamford alternators, Class H insulation, ±1% voltage regulation, and DSE 6120 MKIII controllers, it ensures CPCB-IV+ compliant performance, while a 990L fuel tank, 60L lube oil, 161L coolant, and 80L DEF tank support durable heavy-duty operation in a compact 7500 kg design.
The Greaves GPW-PIV-750 CP delivers 750/600 kVA/kWe prime output, powered by a 6M33G4D4/5 six-cylinder inline TCAC engine with an electronic G3-class governor. With Stamford alternators, Class H insulation, ±1% voltage regulation, and DIEF SGC 420 controllers, it ensures CPCB-IV+ compliant performance, while a 990L fuel tank, 61L lube oil, 159L coolant, and twin 90L DEF tanks support efficient heavy-duty operation in a compact 9810 kg design.
The Greaves GPW-1010 delivers a prime output of 1010/808 kVA/kWe, powered by a 12-cylinder TCAC engine with electronic G3-class governor and isochronous regulation. Equipped with CG alternators, Class H insulation, ±5% voltage regulation, and DSE 7320 MKII controllers, it ensures reliable, CPCB-IV+ compliant operation. With a 990L fuel tank, 114L lube oil, and 200L coolant system, this robust genset is engineered for durability and efficiency.
The Greaves GPW-1250 delivers 1250/1000 kVA/kWe prime output, powered by a 12-cylinder TCAC engine with an electronic G3-class governor. With CG alternators, Class H insulation, ±5% voltage regulation, and DSE 7320 MKII controllers, it ensures CPCB-IV+ compliant operation, while a 990L fuel tank, 155L lube oil, and 250L coolant system support continuous heavy-duty loads in a robust 13,000 kg design.
The Greaves GPW-1500 delivers 1500/1200 kVA/kWe prime output, powered by a 12-cylinder TCAC engine with an electronic G3-class governor. With CG alternators, Class H insulation, ±5% voltage regulation, and DSE 7320 MKII controllers, it ensures CPCB-IV+ compliant operation, while a 990L fuel tank, 155L lube oil, and 310L coolant system support durable heavy-duty performance in a robust 14,000 kg design.
The Greaves GPW-2000 delivers 2000/1600 kVA/kWe prime output, powered by a 16-cylinder V-Type TCAC engine with ECU-controlled isochronous performance. Featuring CG/LS alternators, Class H insulation, ±1% voltage regulation, and a DSE 7320 MKIII controller, it ensures reliable efficiency, while 52.3L displacement, 175L lube oil, and a 542L cooling system enable continuous heavy-duty operation with ISO 8528 and CPCB compliance.